![]() ![]() After selecting the block make sure directory is pointing to iec library folder (was nfpa). If you insert same symbol on the same drawing, you may need to swap the blocks (preciously you had issue with) using command AESWAPBLOCK, select option B.Replace NPFA with IEC as shown below (marked in RED), then save and close.Open WD.ENV (in notepad) which is in the AeData folder (along with the Proj and Tutorial folders).Are they IEC or NFPA (I guess they are NFPA)? Click + of the Schematic Libraries to find out the default symbol libraries.In the Project Settings tab click Schematic Libraries then click Default. ![]() Check your project properties: right click project> properties.Check your project Settings: right click project>Settings, in the lower window you can see what symbol libraries are used – IEC or NFPA?.Just load the library in AutoCAD and go 30 day money-back guarantee. And time money Contains 165 electrical symbols that are easily accessed from a pulldown menu. What is happening here is your project is IEC standard project ie it supposed to symbols from IEC library folder whereas ACADE is defaulted to NFPA standard ie WD.ENV file is telling ACADE to use NFPA Symbols instead. Features: This library will save you hours of drawing time. ![]()